You plan to develop climate and energy strategies with short and long-term goals in your organization?

Contact us

Environmental  laboratories & analysis services

ETLCO is equipped with the latest laboratory and sampling equipment to satisfy the ever-demanding needs for analytical precision. Tests are performed under strict compliance with the latest approved standard methods and procedures (ISO 2017: 17025).

  • Water analyses
  • Soil ,Sludge and Sediment analyses
  • Microbiological testes
  • Metals and trace metals analyses
  • VOC, SVOC, Pesticides & TPH Analysis

FIELD SAMPLING SERVICES

ETLCO provides pickup and sampling with comprehensive field services for our clients.ETLCO understands the importance of schedule coordination and timely completion of projects which being thoroughly achieved by closed coordination between Project Management and sample coordinators. Our well trained and equipped staff performs following successful sampling event.

  • Groundwater Well Sampling
  • Dewatering well Sampling
  • Surface Water Sampling
  • Industrial and Sanitary Wastewater Sampling
  • Soil, Sludge and Sediment Sampling
  • Solids, Non-Aqueous Wastes Sampling
  • Hazardous Industrial Waste Sampling
  • Drinking water Network Sampling
  • Sea water inlet, desal and outfall Sampling

WASTE CHARACTERIZATION

ETLCO provides Waste Characterization analyses for the classification of waste under the RCER2015 standard and EPA regulatory requirements for disposal purposes. Analytical methods include USEPA SW846- methodologies specific for waste characterization, as well as EPA methods for water matrices and client specific methods, where required. Full TCLP (Toxicity Characteristic Leachate Procedure):

  • Volatiles and Semi volatiles
  • Pesticides and Herbicides
  • RCRA Metals (As, Ba, Cd, Cr, Pb,Hg, Se, Ag)

  • TCLP Extraction (US EPA 1311)
  • RCI (Reactivity, Corrosivity, Ignitability):

  • Soil and Waste PH

  • Total Cyanide
  • All analyses adhere to 40 CFR 261.21

  • Compliance analysis for Table5- of RCER2015, (Vol. I)

METALLIC CONSTITUENT ANALYSIS

Metals analyses are routinely performed by our experienced and professionally qualified staff. Samples from different sources such as municipal, commercial, and
petrochemical/ industrial are analyzed for water, wastewater, sludge, and solid matrices.

ETLCO understands the significance of well-timed analysis and reporting to our clients. The requirement of specific reporting format can be met through the consultation of the user prior to project commencement.

  • Inductively Coupled Plasma (ICP-MS) – Metals Analysis EPA Method 200.8 APHA Method 3125, EPA Method 6020 (SW846-)

  • Inductively Coupled Plasma (ICP – OES) – Metals Analysis EPA Method 200.7 APHA Method 3120 EPA Method 6010 (SW846-)

  • ICP-OES with Hydride Gen. Kit – Mercury
DOWNLOAD OUR COMPANY PROFILE FOR MORE DETAILS